Spezifications
Product features
- Economical 150 kW 4-cylinder turbo diesel engine with intercooler
- Electric, regulated fuel injection
- Engine control unit with specially developed SMT-Scharf characteristic map (mapping)
- Dry exhaust gas cooling
- Traction drive with parallel pressing system
- Powerful generator with 4 separate power supplies (3 of them intrinsically safe)
- hydraulic engine starter, optionally remote controlled
- Modular design
- Intrinsically safe control system
- Data exchange with mine IT infrastructure
Advantages
- The state-of-the-art engine control unit complies with all applicable exhaust gas regulations
- The SMT-Scharf specific characteristic diagrams of the engine control unit are optimized in terms of performance, consumption and pollutants
- Parallel power units enable constant contact forces, independent of the direction of travel, and thus enable safe and friction wheel-protecting locomotion
- The modular design allows easy reconfiguration of the train composition by the user at the mine without the mandatory use of new parts. Your DZK is therefore also adaptable to future requirements.
- The dry exhaust gas cooling system is unsurpassed in terms of size and cooling capacity and is the most efficient in this performance class worldwide
Technical data
Configuration | Minimum | Standard | Maximum | |||
DZK3500 2+1 KP | DZK3500 3+3 KP | DZK3500 5+5 KP | ||||
No. of drives | 3 | 6 | 10 | |||
Traction force | 60 | kN | 120 | kN | 200 | kN |
Max. Speed* | 3,4 | m/s | 1,7 | m/s | 1 | m/s |
Holding force | 90 | kN | 198 | kN | 342 | kN |
Diameter friction wheel | 340 mm, optional 450 mm | |||||
Electrical System | ||||||
Operating voltage | 3 x 12 V / 2 A | |||||
Protection class | SYST IM2 Exib I | |||||
Diesel engine | ||||||
Type | 4-Cylinder / Turbo Diesel | |||||
Nominal Power | 150 kW at 2.100 min-1 | |||||
Starter | Hydraulic | |||||
Protection class | ATEX | |||||
Exhaust gas cooling system | capsuled water circuit | |||||
Operating conditions | ||||||
Ambient temperature | -10° C bis +40° C | |||||
Rel. Humidity | 90 % | |||||
Horizontal curve radius | min. 4 m | |||||
Vertical curve radius | min. 8 m | |||||
Max. Rail inclination | 30 Degrees |